Cut to Length with Multi Stroke Program
Guidelines - 0 means the drive is not faulted and not enabled, while 8 means
the drive is not faulted and enabled. Alternating 8.> means actively inhibiting
CW motion and alternating
8.< means actively inhibiting CCW motion
STATUS LED VALUE FAULT MEANING
(Blinking) 1 1 Velocity feedback (VelFB) over speed
(Blinking) 2 2 Motor Over-Temp
(Blinking) 3 3 Drive Over-Temp
(Blinking) 4 4 Drive I*t
(Blinking) 5 5 1-n Fault (9x3)
(Blinking) 6 6 Control ±12 V supply under voltage
(Blinking) 7 7 Output over current or bus over voltage
(Blinking) 9 9 Not Assigned