ISOLATED NORMALLY OPEN CONTACT PROVIDED
TO CUSTOMER. THE CONTACT WILL CLOSE WHEN
THE PRESET COUNT OF THE MULTI-STROKE UNIT
HAS BEEN REACHED (MAX 120 VAC).
NORMALLY CLOSED LIMIT SWITCH (SUPPLIED
BY CUSTOMER) TO BE MOMENTARILY OPENED
AFTER WORK CYCLE OF THE EXTERNAL
EQUIPMENT TO PROVIDE A RESET SIGNAL.
NOTE-1: IF THE RESET SWITCH IS ALLOWED TO
BE HELD OPEN THEN AN UNCONTROLLED START
CYCLE COULD BE INITIATED.
NOTE-2: THE MULTI-STROKE UNIT CYCLE IS
CONTROLLED BY THE PRESS CYCLE. TURNING
OFF THE MULTI-STROKE UNIT BEFORE THE
PRESS CYCLE IS COMPLETE COULD ALLOW THE
PRESS TO CONTINUE CYCLING.
SEQUENCE OF OPERATION
1. SUPPLY 120 VAC TO MULTI-STROKE UNIT THROUGH POWER CORD PROVIDED.
2. PUSH GREEN “ON” PORTION OF POWER PUSHBUTTON.
3. TURN “STOP-START” SELECTOR SWITCH TO THE “START” POSITION, AND RELEASE IT. IT WILL SPRING
RETURN TO THE RUN POSITION.
4. THE FEED WILL BEGIN TO CYCLE FOR THE NUMBER OF STROKES SET ON THE “FEED STROKES PER
CYCLE” ROTARY SWITCH.
5. THE FEED WILL CYCLE AT THE RATE DETERMINED BY THE SETTING ON THE “FEED RATE” POT. (THE
FEED RATE CAN BE DOUBLED THROUGH A TOGGLE SWITCH LOCATED ON THE PRINTED
CIRCUIT BOARD.)
CAUTION: TOO FAST OF A SETTING WILL CAUSE IMPROPER
FEED ACTUATION. MISFEEDING WILL RESULT.
6. AFTER THE FEED HAS OPERATED FOR THE PRESET NUMBER OF STROKES THE FEED WILL STOP
AND THE MULTISTROKE WILL ACTUATE THE SOLID STATE RELAY, PROVIDING THE CUSTOMER WITH AN
ISOLATED CONTACT OUTPUT FOR USE IN HIS EXTERNAL CONTROLS.
7. AFTER THE WORK CYCLE OF THE EXTERNAL EQUIPMENT, A NORMALLY CLOSED LIMIT SWITCH (OR
CONTACT) MUST BE OPENED MOMENTARILY TO PROVIDE A RESET SIGNAL TO THE
MULTISTROKE CONTROL.
8. TURNING THE “START - STOP - RUN” SELECTOR SWITCH TO THE STOP POSITION WILL ALLOW THE
PRESENT FEED STROKE CYCLES TO COMPLETE THE PRESET NUMBER OF STROKES HOWEVER, A
RESET SIGNAL WILL NOT ACTUATE ANOTHER MULTISTROKE PROGRESSION CYCLE.
9. SLIDING THE INITIATE SWITCH TO THE “A” POSITION ALLOWS THE MULTI-STROKE CONTROL TO BE
ACTUATED BY THE EXTERNAL RESET SIGNAL ONLY. IF THE SLIDE SWITCH IS IN THE “B” POSITION THE
SEQUENCE CAN BE INITIATED BY EITHER THE CONSOLE PUSHBUTTON OR THE EXTERNAL RESET SIGNAL.